Accuracy guaranteed for 1 year |
Measurement functions | (1) DC mode, (2) AC mode, (3) RMS mode. |
Input type | Balanced differential input |
Output | Voltage division ratio: 1/1000, BNC terminal (DC/AC/RMS 3-mode selectable output) |
DC amplitude accuracy | ±1% f.s. (1000V DC or less), ±3% f.s. (2000 V DC or less) (f.s.=DC 2000V) |
Output accuracy | ±1% f.s. (DC, 40Hz to 1kHz), ±4% f.s. (1 kHz to 100 kHz) (f.s.=AC 1000V) |
Input resistance, capacity | H-L: 9 MΩ, approx 10 pF (C at 100 kHz) H, L-case: 4.5 MΩ, approx 20 pF (C at 100 kHz) |
Maximum input voltage | 2000V DC, 1000V AC (CAT II), 600V AC/DC (CAT III) |
Maximum rated voltage to earth | When using grabber clip: 1500V AC/DC (CAT II), 600V AC/DC (CAT III) When using alligator clip: 1000V AC/DC (CAT II), 600V AC/DC (CAT III) |
Power supply | - AC ADAPTER 9418-15 (DC 12 V±10%)¹
- Power supply through POWER CORD 9324 connected to logic connector on MEMORY HiCORDER.²
- Power supply through POWER CORD 9325 connected to sensor connector on F/V UNIT 8940.³
- Power supply through POWER CORD 9328 connected to DC jack on Input UNIT 8950/ 8952/ 8953/ 8955, for the MEMORY HiCORDER 8855.
- Power supply through POWER CORD 9248 connected to the PROBE POWER UNIT 9687, for MEMORY HiCORDER 8860-50/ 8861-50.
¹ Operating voltage range: +5 to +12V, less than 300mA. DC jack OD 5.5 mm, ID 2.1 mm ² Power jack on probe connects to logic connector on MEMORY HiCORDER through the POWER CORD 9324. Up to "4 power cords" can be connected to the MEMORY HiCORDER 8826, Only "1 cord" can be connected to the MEMORY HiCORDER 8841, 8842, 8835 or 8835-01. With the 8841, 8842, 8835, and 8835-01, the DIFFERENTIAL PROBE 9322 cannot be used in combination with the LOGIC PROBEs 9320 and 9321. With the 8826, the 9322 can be used with the 9320/9321 in the following combinations. "9324 × 4 with no 9320/9321" "9324 × 3 and 9320/9321 × 4" "9324 × 2 and 9320/9321 × 6" "9324 × 1 and 9320/9321 × 7" ³Power jack on probe connects to sensor connector on the F/V UNIT 8940 through the POWER CORD 9325. Up to "6 power cords" 9325 can be used with the MEMORY HiCORDERs 8826, 8841, and 8842, and up to "4 power cords" can be used with the MEMORY HiCORDER 8835-01. When used in combination with the CLAMP SENSORs 3273 or 9270 series, up to "6 power cords" can be used in combination with the 8826 and up to "4 power cords" can be used in combination with the 8841, 8842, and 8835-01. |
Dimensions, mass | 70 (2.76in) W × 150 (5.91in) H × 25 (0.98in) D mm, approx. 350g (12.3oz) |
Cable length | Main unit cable 1.3m (4.27ft), input section cable 46cm (1.51ft) |
Supplied accessories | Alligator clips (2), Grabber clips (2), CARRYING CASE 3853 (1) |