구입 및 기술문의 : 010-4221-0660
Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CT7736 is a 600 A AC/DC Current Sensor that pairs with the detachable Display Unit CM7290 or CM7291 for convenient field testing, while delivering an extended temperature range and auto-zero adjustment to minimize drift due to wide temperature changes that occur during long-term testing. Further extend the functionality of this system by connecting the Display Unit with a Hioki memory recorder or logger. CAT IV 600 V Key Features • Accurately measure and record even when the temperature changes • Ideal for site inspections by using detachable Display Unit • Four output formats to output data to loggers or other devices (via Display Unit): WAVE, RMS, PEAK, Hz
Must be paired with the Display Unit CM7290 or CM7291 to operate as a standalone unit. Add an output cord to deliver signals to a data logger or Memory HiCorder for the following types of output: • A DC or AC (up to 5 kHz/10 kHz) current waveform as-is (using WAVE mode for waveform output) • An analog signal generated by converting the input waveform to a series of RMS values (using RMS mode for RMS output) • An analog signal generated by detecting the current waveform’s peak value (using PEAK mode for peak output • An analog waveform generated by detecting the frequency of the current waveform (using FREQ mode for frequency output)
A wide operating temperature range of -25°C to 65°C (-13°F to 149°F) lets you use the sensor even in sub-freezing temperatures and on hot summer days.
Because temperature variations cause the zero-point to shift when using a conventional DC current sensor to measure DC current, it is necessary to perform zero-adjustment periodically when recording data over an extended period of time with such a sensor. This shortcoming is caused by the effects of the Hall element that conventional DC current sensors use to to detect current. Hioki’s new auto-zero current sensors incorporate a new switching-based offset cancellation circuit developed to address this problem. The new design minimizes zero-point shift, making it possible to record DC current values over an extended period of time without the need for periodic zero-adjustment.
Pair with the CM7291 Display Unit to send measurement data to a smartphone or tablet using Bluetooth® wireless technology. Use the GENNECT Cross dedicated app to display and review measured values and waveforms in real time.
Rated measurement current | 600 A AC/DC |
---|---|
Max. measurement current | 600 A (requires derating at frequency) |
Max. allowable peak input | 900 A peak |
Bandwidth | DC to 5 kHz (-3dB) (When used in combination with CM7290 or CM7291: DC 3 Hz to 1 kHz) |
Typical phase accuracy | ±1.8 deg. (DC < f ≤ 66 Hz) |
Output rate | 1 mV/A |
Max. rated voltage to earth | AC/DC 600 V (CAT IV) AC/DC 1000 V (CAT III) |
Core diameter | φ 33 mm (1.30 in) or less |
Output connectors | HIOKI PL 14 |
Operating temperature range | -25 °C to 65 °C (-13 °F to 149 °F) |
Dimensions and mass | 64 mm (2.52 in)W × 160 mm (6.30 in)H × 34 mm (1.34 in)D, 320 g (11.3 oz), Cable length 2.5 m (8.20 ft) |
Accessories | None |
등록된 상품이 없습니다.