Vertical System




Nominal Analog Bandwidth @ Ω 50 10 mV-1 V/div1 GHz
Rise Time (typical)300 ps
Input ConnectorProBus/BNC
Input Channels4
Bandwidth Limiters20 MHz; 200 MHz
Input Impedance1 MΩ || 20 pF or 50 Ω
Input Coupling50 Ω: DC, 1 MΩ: AC, DC, GND
Maximum Input Voltage50 Ω: 5 Vrms, 1 MΩ: 400 V max. (DC + Peak AC = 5 kHz)
Vertical Resolution8 bits; up to 11 with enhanced resolution (ERES)
Sensitivity50 Ω: 2 mV/div–1 V/div fully variable; 1 MΩ: 2 mV–10 V/div fully variable
Offset Range±400 mv@2–4.95 mv/div, ±1 V@5–99 mv/div, ±10 V @ 100 mv–1 V/div, ±100V @ 1.02–10 V/div; 1 M O: ±400 mv @ 2–4.95 mv/div, ±1 V @ 5–99 mv/div, ±10V @ 100 mv–1 V/div, ±100V @ 1.02–10 V/div
 

Main Specifications



ProbesOne PP007 per channel standard; Optional passive and active probes available.
 

Timebase System




Roll ModeUser selectable at <= 500 ms/div and <= 100 kS/s
 

Horizontal System




TimebasesInternal timebase common to all input channels; an external clock may be applied at the auxiliary input
Time/Division RangeReal time: 200 ps/div–10 s/div, RIS mode: 200 ps/div to 10 ns/div, Roll mode: up to 1,000 s/div
Clock Accuracy<= 5 ppm @ 25 °C (typical) (<= 10 ppm @ 5–40 °C)
Sample Rate and Delay Time AccuracyEqual to Clock Accuracy
Trigger and Interpolator JitterJitter <=3 ps rms (typical)
Channel-Channel Deskew Range±9 x time/div setting, 100 ms max., each channel
External ClockDC to 600 MHz; (DC to 1 GHz for 104Xi and 204Xi) 50 Ω, (limited BW in 1 MΩ), BNC input, limited to 2 Ch operation (1 Ch in 62Xi-A), (minimum rise time and amplitude requirements apply at low frequencies)
 

Acquisition System




Single-Shot Sample Rate/Ch5 GS/s
Random Interleaved Sampling (RIS)200 GS/s
Maximum Trigger Rate1,250,000 waveforms/second
Interleaved Sample Rate (2 Ch)10 GS/s
RIS ModeUser selectable from 100 ps/div to 10 ns/div
Acquisition Memory OptionsMax. Acquisition Points (4 Ch/2 Ch, 2 Ch/1 Ch in 62Xi-A) Segments (Sequence Mode)
Sequence Time Stamp Resolution1 ns
Standard Memory12.5M/25M 10,000
 

Acquisition Processing




AveragingSummed and continuous averaging to 1 million sweeps
Enhanced Resolution (ERES)From 8.5 to 11 bits vertical resolution
Envelope (Extrema)Envelope, floor, or roof for up to 1 million sweeps
InterpolationLinear or (Sinx)/x
Time Resolution (min, Single-shot)100 ps (10 GS/s)
 

Triggering System




Trigger ModesNormal, Auto, Single, Stop
SourcesAny input channel, External, Ext/10, or Line; slope and level unique to each source, except Line
CouplingDC, AC (typically 7.5 Hz), HF Reject, LF Reject
Pre-trigger Delay0–100% of memory size (adjustable in 1% increments, or 100 ns)
Post-trigger DelayUp to 10,000 divisions in real time mode, limited at slower time/div settings in roll mode
Hold-off by Time or Events1 ns to 20 s or 1 to 1,000,000,000 events
Internal Trigger Range±4.1 div from center (typical)
Trigger Sensitivity with Edge Trigger (Ch 1–4)2 div @ < 1 GHz 1 div @ < 200 MHz
Max. Trigger Frequency, SMART Trigger1 GHz @ = 10 mV
External Trigger Input RangeEXT/10 ±4 V; EXT ±400 mV
Minimum Time Between Sequential Segments Sequential Segments800 ns
 

Basic Triggers




EdgeTriggers when signal meets slope (positive, negative, or Window) and level condition.
TV-Composite VideoTriggers selectable fields (1, 2, 4, or 8), Positive or Negative slope, or Line (up to 1500), for NTSC, PAL, SECAM, or non-standard video (up to 1500 lines).
 

SMART Triggers




State or Edge QualifiedTriggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events.
DropoutTriggers if signal drops out for longer than selected time between 1 ns and 20 s.
PatternLogic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input – 2 Ch+EXT on WaveRunner 62Xi-A). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pa
 

SMART Triggers with Exclusion Technology




Glitch and Pulse WidthTriggers on positive or negative glitches with widths selectable from 500 ps to 20 s or on intermittent faults (subject to bandwidth limit of oscilloscope).
Signal or Pattern IntervalTriggers on intervals selectable between 1 ns and 20 s.
Timeout (State/Edge Qualified)Triggers on any source if a given state (or transition edge) has occurred on another source. Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events.
RuntTrigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 s.
Slew RateTrigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 s.
Exclusion TriggeringTrigger on intermittent faults by specifying the normal width or period.
 

Color Waveform Display




TypeColor 10.4" flat-panel TFT-LCD with high resolution touch screen
ResolutionSVGA; 800 x 600 pixels; maximum external monitor output resolution of 2048 x 1536 pixels
Number of tracesDisplay a maximum of 8 traces. Simultaneously display channel, zoom, memory, and math traces.
Grid StylesAuto, Single, Dual, Quad, Octal, XY, Single + XY, Dual + XY
Waveform RepresentationSample dots joined or dots only in real-time mode
 

Internal Waveform Memory




Internal Waveform MemoryM1, M2, M3, M4 Internal Waveform Memory (store full-length waveform with 16 bits/data point) or store to any number of files limited only by data storage media.
 

LeCroy WaveStream™ Fast Viewing Mode




Intensity256 Intensity Levels, 1–100% adjustable via front panel control
Number of Channelsup to 4 simultaneously
Max Sampling Rate5 GS/s (10 GS/s for WaveRunner 62Xi-A, 64Xi-A, 104Xi-A, 204Xi-A in interleaved mode)
Waveformsup to 8000 waveforms/second
OperationFront panel toggle between normal real-time mode and LeCroy WaveStream Fast Viewing mode
 

Setup and Waveform Storage

Front Panel and Instrument StatusStore to the internal hard drive, over the network, or to a USB-connected peripheral device.
 

Zoom Expansion Traces




Zoom Expansion TracesDisplay up to 4 Zoom/Math traces with 16 bits/data point
 

Interface




Remote ControlVia Windows Automation, or via LeCroy Remote Command Set
GPIB Port (optional)Supports IEEE – 488.2
Ethernet Port10/100/1000Base-T Ethernet interface (RJ-45 connector)
USB (Host)5 USB 2.0 ports (one on front of instrument) supports Windows-compatible devices.
External Monitor PortStandard 15-pin D-Type SVGA-compatible DB-15; connect a second monitor to use extended desktop display mode with XGA resolution.
Serial PortDB-9 RS-232 port (not for remote oscilloscope control)
 

Auxiliary Input




Signal TypesSelected from External Trigger or External Clock input on front panel
Coupling50 Ω: DC, 1 MΩ: AC, DC, GND
Maximum Input Voltage50 Ω: 5 Vrms, 1 MΩ: 250 V max. (DC + Peak AC = 5 kHz)
 

Auxiliary Output




Signal TypesTrigger Enabled, Trigger Output. Pass/Fail, or Off
Output SignalTTL, ˜3.3 V
Calibrator SignalOutput available on front panel connector provides a variety of signals for probe calibration and compensation.
 

Automatic Setup




Auto SetupAutomatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals.
Vertical Find ScaleAutomatically sets the vertical sensitivity and offset for the selected channels to display a waveform with maximum dynamic range.
 

General




Auto CalibrationEnsures specified DC and timing accuracy is maintained for 1 year minimum.
Power Requirements90–264 Vrms at 50/60 Hz; 115 Vrms (±10%) at 400 Hz, Automatic AC Voltage Selection Installation Category: 300V CAT II; Max. Power Consumption: 340 VA/340 W; 290 VA/290 W for WaveRunner 62Xi-A
 

Probes




Probe System: ProBusAutomatically detects and supports a variety of compatible probes.
Scale FactorsAutomatically or manually selected, depending on probe used
 

Environmental and Safety




Temperature (Operating)+5 °C to +40 °C
Temperature (Non-Operating)-20 °C to +60 °C
Humidity (Operating)Maximum relative humidity 80% for temperatures up to 31 °C decreasing linearly to 50% relative humidity at 40 °C
Humidity (Non-Operating)5% to 95% RH (non-condensing) as tested per MIL-PRF-28800F
Altitude (Operating)Operating Up to 2,000 m
Altitude (Non-Operating)Non-Operating 12,190 m
 

Physical Dimensions




Dimensions (HWD)260 mm x 340 mm x 152 mm Excluding accessories and projections (10.25" x 13.4" x 6")
Net Weight6.95 kg. (15.5 lbs.)

 