중고구입 및 렌탈 문의 : 010-4221-0660
Vertical System | |
| Nominal Analog Bandwidth @ Ω 50 10 mV-1 V/div | 1 GHz |
| Rise Time (typical) | 300 ps |
| Input Connector | ProBus/BNC |
| Input Channels | 4 |
| Bandwidth Limiters | 20 MHz; 200 MHz |
| Input Impedance | 1 MΩ || 20 pF or 50 Ω |
| Input Coupling | 50 Ω: DC, 1 MΩ: AC, DC, GND |
| Maximum Input Voltage | 50 Ω: 5 Vrms, 1 MΩ: 400 V max. (DC + Peak AC = 5 kHz) |
| Vertical Resolution | 8 bits; up to 11 with enhanced resolution (ERES) |
| Sensitivity | 50 Ω: 2 mV/div–1 V/div fully variable; 1 MΩ: 2 mV–10 V/div fully variable |
| Offset Range | ±400 mv@2–4.95 mv/div, ±1 V@5–99 mv/div, ±10 V @ 100 mv–1 V/div, ±100V @ 1.02–10 V/div; 1 M O: ±400 mv @ 2–4.95 mv/div, ±1 V @ 5–99 mv/div, ±10V @ 100 mv–1 V/div, ±100V @ 1.02–10 V/div |
Main Specifications | |
| Probes | One PP007 per channel standard; Optional passive and active probes available. |
Timebase System | |
| Roll Mode | User selectable at <= 500 ms/div and <= 100 kS/s |
Horizontal System | |
| Timebases | Internal timebase common to all input channels; an external clock may be applied at the auxiliary input |
| Time/Division Range | Real time: 200 ps/div–10 s/div, RIS mode: 200 ps/div to 10 ns/div, Roll mode: up to 1,000 s/div |
| Clock Accuracy | <= 5 ppm @ 25 °C (typical) (<= 10 ppm @ 5–40 °C) |
| Sample Rate and Delay Time Accuracy | Equal to Clock Accuracy |
| Trigger and Interpolator Jitter | Jitter <=3 ps rms (typical) |
| Channel-Channel Deskew Range | ±9 x time/div setting, 100 ms max., each channel |
| External Clock | DC to 600 MHz; (DC to 1 GHz for 104Xi and 204Xi) 50 Ω, (limited BW in 1 MΩ), BNC input, limited to 2 Ch operation (1 Ch in 62Xi-A), (minimum rise time and amplitude requirements apply at low frequencies) |
Acquisition System | |
| Single-Shot Sample Rate/Ch | 5 GS/s |
| Random Interleaved Sampling (RIS) | 200 GS/s |
| Maximum Trigger Rate | 1,250,000 waveforms/second |
| Interleaved Sample Rate (2 Ch) | 10 GS/s |
| RIS Mode | User selectable from 100 ps/div to 10 ns/div |
| Acquisition Memory Options | Max. Acquisition Points (4 Ch/2 Ch, 2 Ch/1 Ch in 62Xi-A) Segments (Sequence Mode) |
| Sequence Time Stamp Resolution | 1 ns |
| Standard Memory | 12.5M/25M 10,000 |
Acquisition Processing | |
| Averaging | Summed and continuous averaging to 1 million sweeps |
| Enhanced Resolution (ERES) | From 8.5 to 11 bits vertical resolution |
| Envelope (Extrema) | Envelope, floor, or roof for up to 1 million sweeps |
| Interpolation | Linear or (Sinx)/x |
| Time Resolution (min, Single-shot) | 100 ps (10 GS/s) |
Triggering System | |
| Trigger Modes | Normal, Auto, Single, Stop |
| Sources | Any input channel, External, Ext/10, or Line; slope and level unique to each source, except Line |
| Coupling | DC, AC (typically 7.5 Hz), HF Reject, LF Reject |
| Pre-trigger Delay | 0–100% of memory size (adjustable in 1% increments, or 100 ns) |
| Post-trigger Delay | Up to 10,000 divisions in real time mode, limited at slower time/div settings in roll mode |
| Hold-off by Time or Events | 1 ns to 20 s or 1 to 1,000,000,000 events |
| Internal Trigger Range | ±4.1 div from center (typical) |
| Trigger Sensitivity with Edge Trigger (Ch 1–4) | 2 div @ < 1 GHz 1 div @ < 200 MHz |
| Max. Trigger Frequency, SMART Trigger | 1 GHz @ = 10 mV |
| External Trigger Input Range | EXT/10 ±4 V; EXT ±400 mV |
| Minimum Time Between Sequential Segments Sequential Segments | 800 ns |
Basic Triggers | |
| Edge | Triggers when signal meets slope (positive, negative, or Window) and level condition. |
| TV-Composite Video | Triggers selectable fields (1, 2, 4, or 8), Positive or Negative slope, or Line (up to 1500), for NTSC, PAL, SECAM, or non-standard video (up to 1500 lines). |
SMART Triggers | |
| State or Edge Qualified | Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events. |
| Dropout | Triggers if signal drops out for longer than selected time between 1 ns and 20 s. |
| Pattern | Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input – 2 Ch+EXT on WaveRunner 62Xi-A). Each source can be high, low, or don’t care. The High and Low level can be selected independently. Triggers at start or end of the pa |
SMART Triggers with Exclusion Technology | |
| Glitch and Pulse Width | Triggers on positive or negative glitches with widths selectable from 500 ps to 20 s or on intermittent faults (subject to bandwidth limit of oscilloscope). |
| Signal or Pattern Interval | Triggers on intervals selectable between 1 ns and 20 s. |
| Timeout (State/Edge Qualified) | Triggers on any source if a given state (or transition edge) has occurred on another source. Delay between sources is 1 ns to 20 s, or 1 to 99,999,999 events. |
| Runt | Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 s. |
| Slew Rate | Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 s. |
| Exclusion Triggering | Trigger on intermittent faults by specifying the normal width or period. |
Color Waveform Display | |
| Type | Color 10.4" flat-panel TFT-LCD with high resolution touch screen |
| Resolution | SVGA; 800 x 600 pixels; maximum external monitor output resolution of 2048 x 1536 pixels |
| Number of traces | Display a maximum of 8 traces. Simultaneously display channel, zoom, memory, and math traces. |
| Grid Styles | Auto, Single, Dual, Quad, Octal, XY, Single + XY, Dual + XY |
| Waveform Representation | Sample dots joined or dots only in real-time mode |
Internal Waveform Memory | |
| Internal Waveform Memory | M1, M2, M3, M4 Internal Waveform Memory (store full-length waveform with 16 bits/data point) or store to any number of files limited only by data storage media. |
LeCroy WaveStream™ Fast Viewing Mode | |
| Intensity | 256 Intensity Levels, 1–100% adjustable via front panel control |
| Number of Channels | up to 4 simultaneously |
| Max Sampling Rate | 5 GS/s (10 GS/s for WaveRunner 62Xi-A, 64Xi-A, 104Xi-A, 204Xi-A in interleaved mode) |
| Waveforms | up to 8000 waveforms/second |
| Operation | Front panel toggle between normal real-time mode and LeCroy WaveStream Fast Viewing mode |
Setup and Waveform Storage | |
| Front Panel and Instrument Status | Store to the internal hard drive, over the network, or to a USB-connected peripheral device. |
Zoom Expansion Traces | |
| Zoom Expansion Traces | Display up to 4 Zoom/Math traces with 16 bits/data point |
Interface | |
| Remote Control | Via Windows Automation, or via LeCroy Remote Command Set |
| GPIB Port (optional) | Supports IEEE – 488.2 |
| Ethernet Port | 10/100/1000Base-T Ethernet interface (RJ-45 connector) |
| USB (Host) | 5 USB 2.0 ports (one on front of instrument) supports Windows-compatible devices. |
| External Monitor Port | Standard 15-pin D-Type SVGA-compatible DB-15; connect a second monitor to use extended desktop display mode with XGA resolution. |
| Serial Port | DB-9 RS-232 port (not for remote oscilloscope control) |
Auxiliary Input | |
| Signal Types | Selected from External Trigger or External Clock input on front panel |
| Coupling | 50 Ω: DC, 1 MΩ: AC, DC, GND |
| Maximum Input Voltage | 50 Ω: 5 Vrms, 1 MΩ: 250 V max. (DC + Peak AC = 5 kHz) |
Auxiliary Output | |
| Signal Types | Trigger Enabled, Trigger Output. Pass/Fail, or Off |
| Output Signal | TTL, ˜3.3 V |
| Calibrator Signal | Output available on front panel connector provides a variety of signals for probe calibration and compensation. |
Automatic Setup | |
| Auto Setup | Automatically sets timebase, trigger, and sensitivity to display a wide range of repetitive signals. |
| Vertical Find Scale | Automatically sets the vertical sensitivity and offset for the selected channels to display a waveform with maximum dynamic range. |
General | |
| Auto Calibration | Ensures specified DC and timing accuracy is maintained for 1 year minimum. |
| Power Requirements | 90–264 Vrms at 50/60 Hz; 115 Vrms (±10%) at 400 Hz, Automatic AC Voltage Selection Installation Category: 300V CAT II; Max. Power Consumption: 340 VA/340 W; 290 VA/290 W for WaveRunner 62Xi-A |
Probes | |
| Probe System: ProBus | Automatically detects and supports a variety of compatible probes. |
| Scale Factors | Automatically or manually selected, depending on probe used |
Environmental and Safety | |
| Temperature (Operating) | +5 °C to +40 °C |
| Temperature (Non-Operating) | -20 °C to +60 °C |
| Humidity (Operating) | Maximum relative humidity 80% for temperatures up to 31 °C decreasing linearly to 50% relative humidity at 40 °C |
| Humidity (Non-Operating) | 5% to 95% RH (non-condensing) as tested per MIL-PRF-28800F |
| Altitude (Operating) | Operating Up to 2,000 m |
| Altitude (Non-Operating) | Non-Operating 12,190 m |
Physical Dimensions | |
| Dimensions (HWD) | 260 mm x 340 mm x 152 mm Excluding accessories and projections (10.25" x 13.4" x 6") |
| Net Weight | 6.95 kg. (15.5 lbs.) |
등록된 상품이 없습니다.