The Agilent DSO7054B offers a sample rate of 2 GSa/s and 8 Mpts of waveform memory. With MegaZoom III technology and a high-definition large XGA LCD display that offers up to 12 bits of vertical resolution, the DSO7054B has advanced technology that will allow you to see more subtle signal detail and more infrequent events than any other scope on the market.
The Agilent InfiniiVision DSO7054B offers a bandwidth of 500 MHz. Each model, equipped with a large 12.1” XGA LCD display, comes in a whisper-quiet package that is just 6.5” deep and weighs only 13 pounds.
Capture long streams of serial data and gain fast insight into your problems. Agilent 7000B Series oscilloscopes provide the best serial protocol capabilities in their class.
Additional Features:
Acquisition: scope channels
| |
Sample rate | MSO/DSO701xA: 2 GSa/s each channel MMSO/DSO703xA: 2 GSa/sec each channel MSO/DSO705xA/710xA: 4 GSa/sec half channel*, 2 GSa/sec each channel Equivalent-time sample rate: 400 GSa/s (when real-time mode is turned off) |
Memory depth Standard | 2 channels/4 channels 8 Mpts/4 Mpts |
Vertical resolution | 8 bits |
Peak detection | MSO/DSO701xA: 500-ps peak detect MSO/DSO703xA: 500-ps peak detect MSO/DSO705xA/710xA: 250-ps peak detect |
Averaging | Selectable from 2, 4, 8, 16, 32, 64 … to 65536 |
High resolution mode | Average mode with avg = 1 12 bits of resolution when ≥10 µs/div at 4 GSa/s or ≥20-µs/div at 2 GSa/s |
Filter | Sinx/x interpolation (single shot BW = sample rate/4 or bandwidth of scope, whichever is less) with vectors on and in real-time mode |
Vertical system: scope channels | |
Scope channels | MSO/DSO7xx2A: Ch 1 and 2 simultaneous acquisition MSO/DSO7xx4A: Ch 1, 2, 3 and 4 simultaneous acquisition |
Bandwidth (–3 dB)* | MSO/DSO701xA: DC to 100 MHz MSO/DSO703xA: DC to 350 MHz MSO/DSO705xA: DC to 500 MHz MSO/DSO710xA: DC to 1 GHz |
AC coupled | MSO/DSO701xA: 3.5 Hz to 100 MHz MSO/DSO703xA: 3.5 Hz to 350 MHz MSO/DSO705xA: 3.5 Hz to 500 MHz MSO/DSO710xA: 3.5 Hz to 1 GHz |
Calculated rise time (=0.35/bandwidth) | MSO/DSO701xA: 3.5 nsec MSO/DSO703xA: 1 nsec MSO/DSO705xA: 700 psec MSO/DSO710xA: 350 psec |
Single-shot bandwidth | MSO/DSO701xA: 100 MHz MSO/DSO703xA: 350 MHz MSO/DSO705xA: 500 MHz MSO/DSO710xA: 1 GHz (in half-channel mode) |
Range | MSO/DSO701xA, MSO/DSO703xA and MSO/DSO705xA: 2 mV/div to 5 V/div (1 MΩ or 50 Ω) MSO/DSO710xA: 2 mV/div to 5 V/div (1 MΩ), 2 mV/div to 1 V/div (50 Ω) |
Maximum input | CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk CAT II 100 Vrms, 400 Vpk With 10073C 10:1 probe: CAT I 500 Vpk, CAT II 400 Vpk |
Offset range | ±5 V on ranges <10 mV/div; ±20 V on ranges 10 mV/div to 200 mV/div; ±75 V on ranges >200 mV/div |
Dynamic range | ±8 div |
Input impedance | 1 MΩ ± 1% || 14 pF or 50 Ω ± 1.5%, selectable |
Coupling | AC, DC |
BW limit | 25 MHz selectable |
Channel-to-channel isolation | DC to max bandwidth >40 dB |
Standard probes | 10073C shipped standard for each scope channel (1165A probes optional) |
Probe ID | Auto probe sense and AutoProbe interface Agilent- and Tektronix-compatible passive probe sense |
Vertical system: scope channels (continued) | |
ESD tolerance | ±2 kV |
Noise, RMS, input shorted | MSO/DSO701xA: 0.50% FS or 300 µV, whichever is greater MSO/DSO703xA: 0.50% FS or 300 µV, whichever is greater MSO/DSO705xA: 0.50% FS or 360 µV, whichever is greater MSO/DSO710xA: 0.65% FS or 360 µV, whichever is greater |
DC vertical gain accuracy | ±2.0% full scale |
DC vertical offset accuracy | ≤200 mV/div: ±0.1 div ±2.0 mV ±0.5% offset value; >200 mV/div: ±0.1 div ±2.0 mV ±1.5% offset value |
Single cursor accuracy | ±{DC vertical gain accuracy + DC vertical offset accuracy + 0.2% full scale (~1/2 LSB)} Example: for 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, accuracy = ±{2.0% (80 mV) + 0.1 (10 mV) + 2.0 mV + 0.5% (5 mV) + 0.2% (80 mV)} = ± 4.785 mV |
Dual cursor accuracy | ±{DC vertical gain accuracy + 0.4% full scale (~1 LSB)} Example: for 50 mV signal, scope set to 10 mV/div (80 mV full scale), 5 mV offset, accuracy = ±{2.0% (80 mV) + 0.4% (80 mV)} = ±1.92 mV |
Horizontal | |
Range | MSO/DSO701xA: 2 nsec/div to 50 sec/div MSO/DSO703xA: 2 nsec/div to 50 sec/div MSO/DSO705xA: 1 nsec/div to 50 sec/div MSO/DSO710xA: 500 psec/div to 50 sec/div |
Resolution | 2.5 ps |
Time scale accuracy | ≤ ± (15+2* (instrument age in years)) ppm |
Vernier | 1-2-5 increments when off, ~25 minor increments between major settings when on |
Delay range | Pre-trigger (negative delay): Greater of 1 screen width or 1 ms Post-trigger (positive delay): 1 s to 500 seconds |
Analog delta-t accuracy | Same channel: ±0.0015% reading ±0.1% screen width ±20 ps Channel-to-channel: ±0.0015% reading ±0.1% screen width ±40 ps Same channel example (MSO/DSO705xA): For signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width), delta-t accuracy = ±{0.0015% (10 µs) + 0.1% (50 µs) + 20 ps} = 50.17 ns |
Logic delta-t accuracy | Same channel: ±0.005% reading ±0.1% screen width ±(1 logic sample period, 1 ns) Channel-to-channel: ±0.005% reading ±0.1% screen width ±(1 logic sample period) ±chan-to-chan skew Same channel example: For signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width), delta-t accuracy = ±{0.005% (10 µs) + 0.1% (50 µs) + 1 ns} = 51.5 ns |
Modes | Main, zoom, roll, XY, segmented (optional) |
Modes | Bandwidth: Max bandwidth Phase error at 1 MHz: < 0.5 degrees Z Blanking: 1.4 V blanks trace (use external trigger on MSO/DSO7xx2A, channel 4 on MSO/DSO7xx4A) |
Reference positions | Left, center, right |
Trigger system | 8 µs (minimum time between trigger events) |
Horizontal | |
Sources | MSO7xx2A: Ch 1, 2, line, ext, D15 - D0 DSO7xx2A: Ch 1, 2, line, ext MSO7xx4A: Ch 1, 2, 3, 4, line, ext, D15 - D0 DSO7xx4A: Ch 1, 2, 3, 4, line, ext |
Modes | Auto, normal (triggered), single |
Holdoff time | ~60 ns to 10 seconds |
Trigger jitter | 15 ps rms |
Trigger system | |
Nth edge burst | Trigger on the Nth edge of a burst that occurs after an idle time that you specify. Max edge count: 65,536. |
Autoscale | Finds and displays all active scope and logic (for 7000 Series MSO) channels, sets edge trigger mode on highest-numbered channel, sets vertical sensitivity on scope channels and thresholds on logic channels, time base to display ~1.8 periods. Requires minimum voltage >10 mVpp, 0.5% duty cycle and minimum frequency >50 Hz. |
Scope channel triggering | |
Range (internal) | ±6 div from center screen |
Sensitivity | <10 mV/div: greater of 1 div or 5 mV; ≥10 mV/div: 0.6 div |
Coupling | AC, ~10 Hz on MSO/DSO701xA/703xA/705xA/710xA, DC, noise reject, HF reject and LF reject (~50 kHz) |